Specifications

16
579 & 595 Installation Instructions
UNIT FIELD WIRING DIAGRAM
GRN/YEL
RUN CAP
RUN CAP
*
CAP
START
PTCR
3105052.033
*
SOME MODELS
SOME MODELS
NOT USED ON
NOT USED ON
COMPRESSOR
C
MOTOR
HERM
C
FAN
GRN/YEL
COMP STARTER
O.L.
R
*
S
4
6
5
3
2
6 PIN CONN
6 PIN CONN
1
RED
WHT
RED
YEL
BLK
WHT
RED
WHT
BRN
WHT
BLU
PASSED
DIELECTRIC
6. Place grill on return air cover and snap in place.
Decal is on end over circuit board.
7. Place slide handle through slots in grill into the
slide posts. Handle will fit in either direction.
8. This completes the installation of the air conditioner.
We recommend that power be supplied to the air
conditioner and check for proper operation. See
section "J. Configuration Of Remote" and refer to
Operating Manual or User's Guide for a description
of the air conditioner operation.
J. CONFIGURATION OF REMOTE
The Hand Held Remote when shipped from Dometic is al-
ways programmed as a cool/furnace model. The dip switches
are located in the hand held remote battery compartment.
See FIG. 33. If the control is to be used with the electric
heat strip or without the furnace its configuration must be
changed as follows:
1. Cool/furnace operation: Dip switches 1,2,& 3 "ON"
- dip switch 4 "OFF".
2. Cool Only-no heat operation: Dip switch 1 & 3 "ON"
- dip switches 2 & 4 "OFF".
3. Cool/Heat operation: Dip switches 1,2,3, & 4 "ON"
-no dip switches "OFF".
Note: After the remote switches are changed, point remote
at the receiver and press the reset button.
BATTERY COMPARTMENT
J1
J2 J3 J4
OFFOFF
FIG. 33
Dip Switches
"ON"
Dip Switches
"OFF"