Specifications

ENGLISH16
HVAC SYSTEM POWERED BY INVERTER AND SEPARATE BATTERY BANKS WITH SEPARATOR -
SHOREPOWER AND CAB POWER OUTLETS
Alternator
Start
Battery 1
Start
Battery 2
-
+
+
-
+
-
HVAC Unit
Dometic Environmental
HVAC System Powered by
Inverter and Separate Battery
Banks with Separator. Shore
power and cab power outlets
NOTES:
1) House Batteries must be of the AGM deep cycle type
2) Alternator must be upgraded. Discuss with Dometic
Applications Department for recommendation.
3) Inverter must be of approved type by Dometic in order
to insure proper operation of system.
4) All added cables shall be of 2/0 or larger, unless
otherwise specified on the drawing.
5) Either bank may have as many or few batteries in
order to provide the desired run time.
-
House
Battery 2
House
Battery 3
+
-
+
House
Battery 4
+
Overcurrent
Protection
Battery
Separator
120VAC Line
DC Wiring
AC Wiring
Shorepower
Inlet
Inverter with Shorepower Pass-Thru
Capability OR Inverter/charger
House
Battery 1
-
+
-
Cab Power
Outlets
Y-Cord
Splitter
Factory Starter
Cable
Factory Negative
alternator cable
Factory Positive
alternator cable
Starter
Add at least a 3/0 cable from the
alternator positive to the starter positive
lug. 3/8" ring terminal at the alternator,
1/2" at the starter.
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
DOMETIC CORP. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
DOMETIC CORP. IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY
USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH
BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATE
NAME
TITLE:
SIZE
B
DWG. NO.
REV
WEIGHT:
SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
E
KEA
9/29/08
SHEET 1 OF 1
Battery 3
DO NOT SCALE DRAWING
Battery-Powered Systems Installation Guidelines