19
Determine cable cross-section
I
The minimum cable cross-section depends on the maximum cable length:
9.1 Connect charging converter
A
Connect the charging converter as shown:
Correct connection diagram: fig. 4, page 5
Connecting the batteries: fig. 5, page 6
Connect control line (I1): fig. 6, page 6
9.2 Connect accessories
I
Connect the accessory to the following contacts:
Performance regulation (I2): fig. 1 5, page 3
Temperature sensor: fig. 1 6, page 3
NOTE
Keep the distance to the body battery as short as possible.
Cable length Minimum cable cross-section/Fuse
2.5 mm² /
30 A
4 mm² /
40 A
6 mm² /
60 A
10 mm² /
80 A
DCCxxxx-10
to the starter battery 7m 11 m 16 m
to battery structure 2m 3.5 m 5m
DCC xxxx–20
to the starter battery 5.5 m 8m 14 m
to battery structure 1.5 m 2.5 m 4m
DCCxxxx-40
to the starter battery 7m
to battery structure 2m
NOTICE!
The charging converter must not be connected directly to the alternator.
NOTE - Performance regulation
To limit the output current of the charging converter to 5 A, a positive
control signal must be present at contact “I2” (fig. 1 5, page 3).