Manual
EN
PerfectCharge Connect charging converter
19
Determine cable cross-section
I
The minimum cable cross-section depends on the maximum cable length:
9.1 Connect charging converter
A
➤ Connect the charging converter as shown:
– Correct connection diagram: fig. 4, page 5
– Connecting the batteries: fig. 5, page 6
– Connect control line (I1): fig. 6, page 6
9.2 Connect accessories
I
➤ Connect the accessory to the following contacts:
– Performance regulation (I2): fig. 1 5, page 3
– Temperature sensor: fig. 1 6, page 3
NOTE
Keep the distance to the body battery as short as possible.
Cable length Minimum cable cross-section/Fuse
2.5 mm² /
30 A
4 mm² /
40 A
6 mm² /
60 A
10 mm² /
80 A
DCCxxxx-10
to the starter battery 7m 11 m 16 m –
to battery structure 2m 3.5 m 5m –
DCC xxxx–20
to the starter battery – 5.5 m 8m 14 m
to battery structure – 1.5 m 2.5 m 4m
DCCxxxx-40
to the starter battery – – – 7m
to battery structure – – – 2m
NOTICE!
The charging converter must not be connected directly to the alternator.
NOTE - Performance regulation
To limit the output current of the charging converter to 5 A, a positive
control signal must be present at contact “I2” (fig. 1 5, page 3).
DCC1224-2424--IO-16s.book Seite 19 Donnerstag, 8. März 2018 3:06 15