7 Connecting the converter
7.1 Connecting the input battery
!
A
Set the main switch (fig. 1 6, page 3) to “0”.
Lay the positive cable (red) (fig. 1 7, page 3) from the converter to positive
terminal of the battery and connect it.
Lay the negative cable (black) (fig. 1 7, page 3) from the converter to negative
terminal of the battery and connect it.
7.2 Connecting the connection cable
You can switch on the device as follows:
Using the main switch on the device (fig. 1 6, page 3)
Using the ignition (fig. 5 A, page 4)
Terminal 15: Connected positive terminal
Using an external switch (fig. 5 B, page 4)
Connecting the converter to be switched on via the main switch
Isolate the connecting line so no malfunction can occur.
Connecting the converter to be switched on via the ignition
Connect the connecting line to terminal 15 (connected positive terminal)
(fig. 5 A, page 4).
Set the main switch (fig. 1 6, page 3) on the back of the converter to “0”
permanently.
WARNING!
Do not reverse the polarity. Reverse polarity of the battery connections
can cause injury and irreversably damage the device.
NOTICE!
Tighten the nuts or bolts to a torque of 12 – 13 Nm. Loose connections
may cause overheating.