User manual

EN
SinePower Connecting the inverter
17
8.3 Mounting the inverter
Hold the inverter against the installation location and mark the fastening points
(fig. 3 A, page 4).
Attach the inverter using your chosen fastening method (fig. 3 B, page 4).
9 Connecting the inverter
9.1 General instructions
!
When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
When setting up a socket distribution circuit (mains setup), comply with the appli-
cable regulations.
Only use copper cables.
Keep the cables as short as possible (< 1 m).
Keep to the specified cable cross section and fit a cable fuse (fig. 4 3, page 4)
as close to the battery as possible on the positive cable (see the table).
WARNING!
The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
Device
Required cable
cross section
Cable fuse
MSI2312T 70 mm² 350 A
MSI2324T 50 mm² 175 A
MSI3512T 95 mm² 400 A
MSI3524T 70 mm² 200 A
MSI2300-3500--IO-16s.book Seite 17 Mittwoch, 3. August 2016 5:46 17