User manual
EN
SinePower Troubleshooting
27
12 Troubleshooting
!
I
The LED (fig. 5 2, page 4) lights up red to indicate the fault:
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
LED display Cause Remedy
Quick flash Input voltage is too high Check the input voltage and reduce it.
Slow flash Input voltage too low The battery needs recharging.
Check the cables and connections.
Occasional flash Overheating Switch off the inverter and the consumer.
Wait 5 to 10 minutes and switch the inverter
on again without any electric consumers.
Reduce the load and make sure the inverter
has better ventilation. Then switch the con-
sumer back on.
Constantly lit Short circuit or reversed
polarity
Excessive load
Switch off the inverter and remove the
consumer.
Then switch the inverter back on without the
consumer. If no excessive load is now shown,
then there is a short circuit in the consumer or
the total load was higher than the power
specified on the data sheet. The fuse in the
device must be pressed in again by hand after
it has been triggered by excess current.
Check the cables and connections.