User manual

EN
SinePower Using the inverter
25
Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches. In this
way, the battery you connect to the inverter is not discharged as quickly.
The inverter operates in energy-saving mode as long as the required power is below
the set level. If the required power exceeds the set level, the inverter works in normal
mode.
The values to be set on your inverter can be found in the following table:
Defining settings
Using the S8 dip switch you can define whether the parameter of the setting should
be made using the connection for the remote control or the dip switches.
Energy-saving mode
DIP switch
S4 S5 S6
Off Off Off Off
2% On Off Off
3% Off On Off
4% On On Off
5% Off Off On
6% On Off On
7% Off On On
8% On On On
Dip switch
Parameter S8
Remote control connection Off
Dip switch On
MSI2300-3500--IO-16s.book Seite 25 Mittwoch, 3. August 2016 5:46 17