18
9.2 Connecting the inverter to the battery
A
I
Set the main switch (fig. 5 3, page 4) to “OFF”.
Loosen the screw (fig. 4 1, page 4) from the red positive terminal (fig. 4 2,
page 4).
Push the cable lug (fig. 4 2, page 4) of the positive cable into the red positive
terminal and fasten it with the bolt.
Connect the negative cable to the black negative cable (fig. 4 4, page 4).
Lay the positive cable from the inverter to the positive terminal of the vehicle
battery and connect it.
Lay the negative cable from the inverter to the negative terminal of the vehicle
battery and connect it. A small spark can occur if the capacitors are being
charged in the inverter.
Connect the earth terminal (fig. 5 8, page 4) to the vehicle chassis.
9.3 Connecting the 230 V power cable
Connect the 230 Vw connection cable with safety plug (fig. 1 3, page 3) to the
230 Vw input jack (fig. 5 6, page 4).
Connect the safety plug to the 230 Vw mains.
9.4 Connecting the 230 V output cable
!
Connect the 230 Vw connection cable with safety plug (fig. 1 2, page 3) to the
230 Vw output jack (fig. 5 7, page 4).
NOTICE!
Make sure that you do not reverse the polarity. Incorrect polarity can
damage the inverter.
NOTE
Tighten the nuts and bolts to a maximum torque of 15 Nm. Loose
connections may cause overheating.
WARNING!
Before connecting the 230 Vw output cable, make sure the inverter is
switched off at the main switch.
MSI2300-3500--IO-16s.book Seite 18 Mittwoch, 3. August 2016 5:46 17