User manual
EN
SinePower Connecting the inverter
17
8.3 Mounting the inverter
➤ Hold the inverter against the installation location and mark the fastening points
(fig. 3 A, page 4).
➤ Attach the inverter using your chosen fastening method (fig. 3 B, page 4).
9 Connecting the inverter
9.1 General instructions
!
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the appli-
cable regulations.
• Only use copper cables.
• Keep the cables as short as possible (< 1 m).
• Keep to the specified cable cross section and fit a cable fuse (fig. 4 3, page 4)
as close to the battery as possible on the positive cable (see the table).
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
Device
Required cable
cross section
Cable fuse
MSI2312T 70 mm² 350 A
MSI2324T 50 mm² 175 A
MSI3512T 95 mm² 400 A
MSI3524T 70 mm² 200 A
MSI2300-3500--IO-16s.book Seite 17 Mittwoch, 3. August 2016 5:46 17