SinePower Connecting the inverter
21
!
➤ Install a residual current circuit breaker in the socket distribution circuit.
9.6 Setting the earthing bridge (fig. 7 8, page 5)
(MSI1800T only)
➤ Remove the earthing screw from the top hole.
➤ Screw the screw into the bottom hole.
9.7 Connecting the MCR-7 or MCR-9 remote control
(accessory)
A
➤ Connect the remote control (accessory) to the remote port (fig. 5 2, page 4).
WARNING! Danger of electrocution!
If you wish to connect more than one appliance to the inverter and install
a socket distribution circuit, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter.
NOTICE!
• Only plug in the connection to the remote control in the remote port.
The device can be damaged by connecting it incorrectly.
• Ensure that the remote control and inverter are supplied with the
same input voltage.
• Follow the instruction manual of the remote control.
MSI900-1800--IO-16s.book Seite 21 Montag, 15. August 2016 1:50 13