User manual

EN
Cleaning and caring for the inverter SinePower
30
11 Cleaning and caring for the inverter
A
Occasionally clean the product with a damp cloth.
12 Troubleshooting
!
I
The ‘Load Status’ LED (fig. 6 3, page 4 to fig. 8 3, page 5) red indicates a fault:
NOTICE!
Do not use sharp or hard objects or cleaning agents for cleaning as these
may damage the product.
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
LED display Cause Remedy
Quick flashing Input voltage is too high Check the input voltage and reduce it.
Slow flashing Input voltage too low The battery needs recharging.
Check the cables and connections.
Occasional flash-
ing
Overheating Switch off the inverter and the load.
Wait about 5 – 10 minutes.
The inverter is being reset.
Then switch the inverter back on without
the load.
Reduce the load and make sure the
inverter has better ventilation. Then switch
the load back on.
MSI900-1800--IO-16s.book Seite 30 Dienstag, 20. Juni 2017 9:59 09