20
8.2 Installation instructions
When selecting the installation location, note the following:
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well ventilated. A ventilation system must be
available for installations in small, enclosed spaces. The minimum clearance
around the inverter must be at least 25 cm (fig. 3, page 3).
The air intake on the underside or the air outlet on the back of the inverter must
remain clear.
For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the inverter under load can lead
to automatic shutdown.
The device must be installed on a level and sufficiently sturdy surface.
A
8.3 Mounting the inverter
Hold the inverter against the installation location you have chosen and mark the
fastening points (fig. 4 A, page 4).
Attach the inverter using your chosen fastening method (fig. 4 B, page 4).
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
MSI900-1800--IO-16s.book Seite 20 Dienstag, 20. Juni 2017 9:59 09