Attach plenum assembly cont.
Raise the plenum assembly towards the roof top
installation.
Engage a M4 x 25 metal thread into one of the 4
holes in the corner of the filter recess.
Raise the plenum and engage the screw into its
mating hole on the diagonal arm of the brace.
Figure 12
Repeat for 3 other threads.
Tighten screws until the plenum has been pulled
up to the ceiling.
Figure 12 - Connect plenum cover to brace arms with 4
M4 x 20 metal threads
In some installations the ceiling may be uneven
and one or more sides of the plenum will require
additional fixtures. Figure 13
IF REQUIRED …..
Screw in #8 x ½” countersunk wood screws
provided.
Tighten until gap is gone.
Install cover caps.
Figure 13 - Extra screws to close gap around plenum
8. Install return air filter
Locate the return air filter. (Item #5).
Align the tabs on one side of the filter body
with matching slots in the plenum. Insert the
filter into the recess in the plenum. Figure 14
Push the filter upwards until both catches
engage and hold the filter in place. Figure 15
Figure 14 - Insert filter tabs into slots
Figure 15 - Push upwards
1. To remove the filter Figure 16:
1. Push both tabs inwards
2. Swing down
Figure 16 - Remove filter from plenum