UNIT SPECIFICATIONS
Condenser set:
Height - 250 mm Above floor
Width - 465 mm
Depth - 440 mm
Weight - 30 kg
Air Handler:
Height - 240 mm
Width - 385 mm
Depth - 250 mm
Weight - 4 kg
Minimum cupboard dimensions:
320 high x 525 wide x 340 deep
Cooling output: 2.2 KW
Heating output: 1.5 KW
Maximum current (cooling): 4.0 amps
Maximum current (heating): 6.5 amps
Maximum locked rotor current: 19 amps
Refrigerant: Australia only R22 or 407C
as marked
Euro production R407C
Charge: 700 grms.
Air volume (max) Air Handler: 110 l/s
Fan (Air handler):
Resistance run wdg.: 165Ω
Resistance aux wdg.: 265Ω
Capacitor: 1.5 mfd. 440 vac
Fan (Condenser set):
Resistance run wdg.: 168Ω
Resistance aux wdg.: 150Ω
Capacitor: 2.5 mfd. 440 vac
Heating element: 1500W
(Pt. No. 4002024)
Refer fitting instructions included
8
AVOID RESTARTING THE COMPRESSOR WITHIN 3 MINUTES OF TURNING OFF
HEATING: (ref fig.16)
NB. The unit will not heat if inside temp. is much above 28°C.
1. Turn fan speed selector to (Heating Speed)
2. Turn mode selector to (Heating)
3. Adjust the thermostat to max. clockwise position.
There will be approximately 30 seconds delay before heating is apparent.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.