Before beginning, mark out the position of the
unit considering the following important
requirements:
DIRECTION OF TRAVEL
DIRECTION OF TRAVEL
- The air conditioner should be situated as
centrally as possible on the van, to ensure even
air distribution.
- The front of the unit MUST face the direction
of travel; failure to follow this instruction will
result in damage to the condenser fans.
- If the caravan is over 23’ in length, or has an
unusually high heat load (see General
Operating Information section regarding
expectations about insulation etc.),
Aircommand would recommend 2 or more
units to cool effectively.
170
450
160 160
14” x 14”
(356mm)
SQUARE
HOLE
- When considering the installation position
remember to check for clearance around the
plenum inside the van.
- Avoid an installation position where a
bulkhead, cupboard or light fitting could
interfere with the discharge air flow from the
plenum.
It is important that the unit is never
more than 5° from the horizontal and
the rear of the unit should never be
higher than the front
- Contact Aircommand if your installation
differs significantly
Fig 2: The foot print of the rooftop unit, and the plenum, measured from the hol
e
- The above outline on the left shows the minimum clearance required around the
CORMORANT unit on the roof of the vehicle, distances shown are calculated from a
14” square hole (356 x 356mm)
- The above outline on the right shows the minimum clearance required around the
Plenum located on the ceiling inside the vehicle, distances shown are calculated from a
14” square hole (356 x 356mm)