Thank you for purchasing the DOME
Leak Sensor, which works with your Z-Wave Cer-
tified Controller to monitor your home for leaks
and for rising water levels in your sump pump.
LED Indicator
Cradle
Lead
Remote Sensor
Metal Feet
Figure 1 - Leak Sensor Front
Including/Connecting into the Z-Wave Network:
Follow the instructions for your Z-Wave certified Controller to
enter inclusion mode.
When prompted by the Controller:
1. For proper inclusion, bring the Leak Sensor to within 10 feet
of your Controller. After inclusion, the device can be moved
to any desired location.
2. Remove the cover of the Leak Sensor by twisting it apart
(Fig 3.)
3. Remove the Battery Tab.
4. Press the Connect Button quickly 3 times in a row.
The LED Indicator will flash five times indicating inclusion.
Battery Tab
LED Indicator
Connect Button
Battery
SolidWorks Student Edition.
For Academic Use Only.
Twist Counter-Clockwise
to Open
Figure 2 - Opening the Leak Sensor
Excluding/Disconnecting from the Z-Wave Network:
Follow the instructions for your Z-Wave certified Controller to
enter exclusion mode.
When prompted by the Controller:
1. Remove the Cover of the Leak Sensor.
2. Press the Connect Button quickly 3 times in a row.
The LED Indicator will flash five times indicating exclusion/dis-
connection.
Resetting the Leak Sensor to Factory Default Settings:
To disconnect from the Z-Wave Network and restore factory default
settings:
1. Open the Back Plate and make sure the Leak Sensor is
powered.
2. Hold the Connect Button for 10 seconds until the LED Indicator
blinks once, then release the button.
Only do this if the controller is disconnected or otherwise unreach-
able!
How to Use—Without Cradle:
You can use the Leak Sensor to monitor most appli-
ances and pipes for leaks without the cradle. Once
included in your Z-Wave system, place the Leak Sensor
on a flat surface near the item you want monitored
where water will collect if it leaks. Make sure all three
Metal Feet are touching the surface.
Metal Feet
Leaking Water
Sensor
When water contacts the
Metal Feet, it will beep
and send an alert to your
Z-Wave Controller notifying
it of the detected water.
Figure 3 - Using the Sensor
Without the Cradle
Figure 4 - Showing the
Metal Feet
How to Use—With Cradle:
To use the cradle, place the sensor into the Cradle,
making sure the Metal Feet make full contact with the
Metal Contacts. It can be placed on a surface or mount-
ed on a wall using the included hardware. The Remote
Sensor Probe plugs into the Cradle through the 3.5mm
minijack.
Figure 5 - The Cradle