Dolphin® Net Base Four-Slot Communication Cradle for the Dolphin® 7900 Mobile Computer ™ Dolphin® 9500 Mobile Computer Dolphin® 9900 Mobile Computer Quick Start Guide !
Dolphin Net Base Quick Start Guide Introduction The Net Base enables up to four mobile computers to communicate with a host device over an Ethernet network. ! We recommend use of Hand Held Products peripherals, power cables, and power adapters. Use of any non-Hand Held Products peripherals, cables, or power adapters may cause damage not covered by the warranty.
Hardware Overview Front Panel Terminal Wells Dock LED Dock LED COMM LED COMM LED Lights solid green when the terminal is properly seated. The terminal can communicate with the Net Base only when properly seated in the well. Indicates the status of data transfer between the Dolphin terminal and the Net Base. Solid Green: Flashing Orange: Indicates a USB connection. Indicates that data is being transferred.
Power Supply Power Adapter Power Connector Cable ON/OFF Switch Power Cord Setting up the Net Base 1. Make sure the ON/OFF switch on the power adapter is in the OFF position. 2. Plug the power cord into the power adapter. 3. Plug the power connector cable into the power connector on the back of the Net Base. 4. Plug the power cord into a standard wall outlet. 5. Plug the CAT-5 Ethernet cable into either of the RJ-45 connectors on the back of the Net Base. 6.
Charging ! We recommend use of Hand Held Products Li-Ion battery packs. Use of any non-Hand Held Products battery may result in damage not covered by the warranty. The Net Base provides power to the Dolphin terminal to allow the Dolphin terminal to charge the main battery of the terminal.
Configuring the Network By default, the Net Base is configured to obtain IP addresses automatically via DHCP server. This means that in most cases you would simply “plug and play” the unit. If necessary, you can use the configuration utility for dynamic network configuration. If Your DNS Server Supports Bind 8.3 or Later 1. Obtain the serial number from the label on the bottom panel of the Net Base. 2. Connect to the network. 3. Power up and wait until the COMM LEDs stop flashing.
4. Enter the user name and default login password to log into Net Base configuration utility. The Net Base menu program displays. SD00032Login: handheld Password: ******** 1) 2) 3) 4) 5) 6) 7) x) View System Configuration View Current Values Express Setup Advanced Setup System Statistics System Diagnostics Help Exit Enter choice: 2 5. Enter choice 2 (View Current Values) to display IP addresses. 6. Record the IP address for the Ethernet port. 7.
Configuring the Net Base with a Static IP Address 1. Connect the serial cable to the Serial DB-9 Connector on the back of the Net Base and a COM port on the host computer. Do NOT connect to the network at this time. 2. On the workstation, start Hyperterminal. Use these settings: 115200 bps, 8,N,1. 3. Wait until login prompt displays on Hyperterminal. 4. Enter the user name and default login password to log into network.
Accessing the Net Base Through a Browser When the Net Base is powered on, connected to the workstation, and you have obtained its IP address, you can access the Net Base through your internet browser. 1. Open your internet browser. 2. In the Address line, type the IP address assigned to the Net Base and press ENTER. 3. The login screen appears showing the Current Values. 4. Enter the Username and Password and click Log On. 5. The home screen appears.
Link Bar Link Click this link to … Current Values Display the current values; this is the default screen. Statistics Display the following system statistics: • • • • • • Diagnostics Iface - The type of interface Docked - Charging status Connect - Status of an active PPP session RX/TX Total - Total bytes received/transmitted RX/TX bps - Instantaneous bits per second RX/TX peak - Peak bits per second Choose from available diagnostic options such as pinging the network host.
Mounting Options The bottom panel offers two mounting options: 1. a DIN Rail for desk mounting or 2. a wall mount kit for wall mounting. Both the DIN Rail and wall mount kits need to be purchased separately. Using the DIN Rail Use a standard 7.5mm high X 35mm wide DIN Rail to mount the Net Base to a horizontal surface, such as a desk or table. Installation Hardware Screw: Washer: Nut: 3/16 in. dia x 5/8 in. long pan head screw 1/2 in. OD x 7/32 in. ID x 3/64 in. thick 3/16 in. dia 1.
Using the Wall Mount Kit You need to purchase two wall mount kits that each contain: • a mounting bracket, • three screws, and • six washer/nut sets. You need two kits so that you have two mounting brackets–one for each end of the device–and enough screws (4) and washer/nut sets (8). The mounting bracket contains an open slot between the back and bottom wedges to accommodate the connector cables. 1. Attach the mounting bracket to the wall using the Recommended Hardware (see page 1-11). 2.
Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 Fax number: (315) 554-6705 E-mail: natechsupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: latechsupport@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@honeywell.
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 Fax: (803) 835-8012 E-mail: naservice@honeywell.
Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment.
Honeywell International Inc. extends these warranties only to users of the products. These warranties are non-transferable. The duration of the limited warranty for the Dolphin Net Base is one year. How to Extend Your Warranty Honeywell International Inc. offers a variety of service plans on our hardware products. These agreements offer continued coverage for your equipment after the initial warranty expires.
16
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Honeywell International Inc. 700 Visions Drive P.O.