Owner Manual

ENGLISH
EN - 22
3.12.d Setting the unit of measurement of temperature
It is possible to choose the set and environment temperature unit of measurement choosing between °C
(Celsius) or °F (Fahrenheit).
Work as follows:
- On the control panel, press the keys + and - at the same time for approximately three seconds.
The desired unit of measurement appears on the display of the control panel.
- On the remote control, keep the central key TEMP pressed for approximately three seconds.
The desired unit of measurement appears on the display of the remote control.
The unit of measurement change must be performed both on the control panel and on the remote
control.
3.12.e Directing the air ow
This function can be activated only from the remote control.
a. Whentheappliancestarts,theapopenscompletely.
b. Press the key “SWING”ontheremotecontrolandtheapstartsoscillatingautomatically.
c. Press the key “SWING”tostoptheapinacertainposition.
Press it again to restart oscillation.
3.12.f Short Cut function
This function can be activated only from the remote control.
a. When the appliance is running in any of its modes, press the key “SHORT CUT” on the remote control
andtheapplianceautomaticallyconguresitselfto“AUTO” with a set temperature of 26°C (80°F).
3.12.g Auto-Restart
a. Iftheapplianceswitcheso󰀨duetointerruptionofpowersupply,itautomaticallyrestartswiththeprevious
settings when electrical power is restored.
4 - MAINTENANCE AND CLEANING
Before proceeding with any maintenance and cleaning
intervention, always make sure you disconnected the
powerplugfromthepowersocket.
Donottouchthemetalpartsoftheappliancewhenyou
removethelter.
Thereisariskofinjuryduetothesharpmetaledges.
Do not use water to clean the internal parts of the air conditioner.
Exposuretowatercanruintheisolation,withtheriskofelectricshocks.