Owner Manual

ENGLISH
EN - 12
2.3 - MOBILE INSTALLATION
The air conditioner must be installed in a suitable environment.
It is recommended to reduce solar radiation through curtains, Venetian blinds and to keep doors and windows
closed.
a. Position the air conditioner in front of a window or French window.
b. Positionthemachinesideterminal(2)ontheexiblehose(1)asshownbyFig.8.
c. Positiontheterminal(3)ontheoppositesideoftheexiblehose(1)(Fig.8).
d. Insertthemachinesideterminal(2)ontheairoutletgridoftheappliance(36)asshowningure9.
e. Position the terminal (3) in such a way as to make air exit to the exterior (Fig.10)
f. If you possess a sliding window (vertical or horizontal) or a shutter, it is possible to use the supplied
“SLIDERKIT”(4)whichallowsamoree󰀩cientinstallation.
FortheinstallationwithKITSLIDER,proceedasshowningures11and12.
g. Apply the adhesive seal (8) (Fig.12)
h. Position the “SLIDER KIT” (4) and adapt it (Fig.12)
i. Positiontheexiblehose(1)andapplytheseal(9)(Fig.12)
l. If desired, position the locking bracket (5) (Fig.12)
Extend the pipe only to the necessary extent, so that the air conveyor remains closed between
the xture shutters.
2.4 - FIXED INSTALLATION
Theairconditionercanalsobeinstalledwithxedholesinwindowsorwalls.
Airowmustnotbeobstructedbyprotectivemeshorsimilar.
Anyformsofprotectionmusthaveatotalcross-sectionforairowofnotlessthan140cm
2
.
a. Positionthemachinesideterminal(2)ontheexiblehose(1)asshownbyFig.8.
b. Drilla127mmholeintheglassorinthewallataheightabovetheoorincludedbetween300and1200
mm (Fig.13).
c. Position the terminal (6) in the wall hole and mark the drilling points (Fig.14).
d. Remove the terminal (6) and drill 6 mm holes (Fig.14).
e. Insert the supplied wallplugs (10) in the holes (Fig.14).
f. Position the terminal(6)intheholeofthewallandxitwiththesuppliedscrews(10)(Fig.15).
g. Insertthemachinesideterminal(2)ontheairoutletgridoftheappliance(36)asshowningure9.
h. Connecttheotherextremityoftheexiblehose(1)ontheterminal(6)(Fig.16).
i. Inserttheange(7)intheterminal(6)andclosethecap(7a)whentheapplianceisnotrunning(Fig.16).
2.5 - ELECTRICAL CONNECTION
Theapplianceisttedwithapowercablewithplug.
Before connecting the air conditioner ensure that:
• Thevoltageandpowerfrequencyvaluesmatchthosespeciedonthe
appliance plate data.
• Thepowerlineisequippedwithane󰀨ectiveearthconnectionandis
correctly sized for maximum power consumption of the air conditioner.