Specifications
9-5
The figure shown below provides an example of good microphone placement.
Figure 9 - 3.
Microphone placement with Cat. No. 580 Multiplexer.
Connect the Cat. No. 582 input/output cable to the Cat. No. 580 Multiplexer and
secure the hold down screws so that the cable cannot work loose. Route the cable
to the location of the CP500 and connect it to the microphone connector on the
back panel of the CP500.
To operate the Cat. No. 580 Microphone Multiplexer through the CP500:
B-Chain Alignment
key
Allignment
key
Format
Selection
Menu
key
Menu
Selection
press:
System
Alignment
screen shows:
screen shows:
press:
press:
screen shows:
Mic Mux
key
B-Chain
Alignment
screen shows:
press:
FORMATS
Menu
Cancel OK
Exit
Begin by entering the microphone
multiplexer control screen on the
CP500:
Press the MENU key.
Press Alignment (SK2).
(A system password may be required at this point)
Press B-chain Alignment (SK1).
Choose Mic Mux (SK3).
NOTE:
While performing equalization, this
multiplexer control screen may be entered directly by
pressing
SK5
.
SK8
OK
To scan through the microphones, press
Scan (SK8).
The scan rate may be set by choosing
Set Scan Rate (SK6). Rotate the front
panel knob until the desired rate is
displayed then press OK. The number
displayed is the time spent connected to
each microphone.