Specifications

7-8
digital system, the performance is perfect up to the limits of error correction, and
then degrades very rapidly. Should the digital data become corrupted beyond
correction through perforation damage, concealment techniques are applied for up
to 4 perforations (40 ms), after which time the CP500 switches to passing analog
audio. Corrected digital data must remain valid for a period of time before
switching back to the digital track.
7.12 Automatic Selection of the Dolby Digital Format
CP500s equipped with versions 1.30 or later software can be set up to sense the
presence of Dolby Digital data on the film and automatically switch to Dolby Digital
from any other format. The section begins with a basic look at how to use this
feature with the standard setup. The latter part of this gives a full explanation of the
auto-digital operation and shows how to modify the operation when using a custom
set-up.
7.12.1 A Quick Look at Operation With Standard
Set-up
The Standard format control screen on the CP500 comes with Formats 01 (Mono),
04 (A-Type), and 05 (Dolby SR) set up so that auto-digital will occur from them.
These formats are marked by an “s” for sources on the screen.
Format 10 is the format that the auto-digital system will switch to when good Dolby
Digital data is detected. It is marked with ana” (for automatic) on the screen. In
this case, Format 10 is defined as the “target” format. For more information on
target formats, see Section 7.12.2.
To enable the auto-digital feature:
MENU
SK7
Press Menu.
Then, press SK7.
Pressing SK7 alternately enables and
disables the auto-digital feature.