Specifications
58 Dolby
®
DP600 Program Optimizer Manual
System Maintenance
2. Pressthered
Power Supply Alarm Resetbuttontoturnoffthewarningalarm,then
disconnectthepowercableonthefailedpowersupplyandloosentheunit’s
thumbscrewbyturningitcounterclockwise,asshowninFigure 3‐13.
Figure3‐13
Figure 3-13 Loosen Thumbscrew on Failed Power Supply
3. Pressthefailedpowersupply’stabtotheleftwhilegraspingitshandleandpulling
theunitoutofitsslot(s ee Figure 3‐14andFigure 3‐15).
Figure3‐14
Figure 3-14 Press on Tab and Pull Handle to Remove Failed Power Supply
Risk of electric shock.
Do not open.
This equipment must be
earthed/grounded.
WARNING
100–240Vac
3.0–1.25A 50/60Hz
Press Alarm Reset button
Disconnect power and
loosen thumbscrew