Specifications

56 Dolby
®
DP600 Program Optimizer Manual
System Maintenance
IfyoureplacedoneoftheRAIDdrives(physicaldrives1or2):
•Usethearrowkeysonthekeyboardtoselect(highlight)theavailabledrive,then
pressthespacebartoselectit.
•UsethearrowkeystoselecttheRAIDmarkedasdegraded,thenpressthespace
barto
selectit.
•Pressthe <Tab>keytoselect
Maintain Unit,thenpress<Enter>.
•Usethearrowkeystoselect
Rebuildinthepopupmenu,thenpress<Enter>.
AlistappearsthatshowswhichRAIDdriveisdesignatedforrebuilding.
•Press<Enter>toselect
OK.
•Press<F8>,thentype
Y toacceptyourentriesandallowtheunittoreboot.
IfyouarerebuildingonlytheRAIDarrayanddidnotreplaceaRAIDdrive:
•UsethearrowkeysonthekeyboardtohighlighttheRAIDmarkedasdegraded,
thenpressthespacebartoselectit.
•Pressthe <Tab>keyto
selectMaintain Unit,thenpress<Enter>.
•Usethearrowkeystoselect
Rebuildinthepopupmenu,thenpress<Enter>.
AlistappearsthatshowswhichRAIDdriveisdesignatedforrebuilding.
•Press<Enter>toselect
OK.
•Press<F8>,thentype
Ytoacceptyourentriesandreboottheunit.
DependingontheoriginalsizeoftheRAIDarray,arebuildwilltakefromoneto
severalhourstocomplete.Duringthistime,thesystemoperatesnormally.
IfyoureplacedasinglenonRAIDdrive(physicaldrives3,4,or5):
•Usethe
arrowkeystohighlightthenewdrivethatappearsintheAvailable Drives
area,thenpressthespacebartoselectit.
•Pressthe<Tab>keytomovetothemenubuttonsatthebottomofthescreen,then
usethearrowkeystoselectthe
Create Unitbutton,andpress<Enter>.
Theavailableunitshouldnowappearinthe
Create a disk array from these drives
box.
•Usethearrowkeystoselectthe
OKbutton,thenpress<Enter>.
•Type
Y toenablethewritecacheonthenewdrive.The3wareBIOSManager
mainscreenreappears.
•Press<F8>toexit,thentype
Ytoacceptyourentriesandreboottheunit.
Whenyoureplaceasingledrive,norebuildtimeisrequired.Thenewdrive
appearsimmediately.
Note: Onsomesmallerkeyboardsyoumayneedtopress<FLock>toenablethe<F8>
functionforthedualusekeys.