Specifications

8 Dolby
®
DP600 Program Optimizer Manual
Introduction
LEDs
2,3,and4indicatethestatusoftheotherthreephysicaldisks.Thesedisksare
configuredasseparatedrivesanddonothaveRAIDbackupcapability.Ifanyofthese
drivesfail,thefaileddrivesmustbereplaced,andany workordersinprogressduringthe
failuremustberestarted.
Ifoneof
thedriveLEDsturnsred,refertoTable 11todeterminewhichphysicaldrive
failed.Typically ,theDP600automaticallyrebuildstheRAIDarraywhenoneoftheRAID
driveshasaproblemorisreplaced(withthepoweron).DuringtheRAIDrebuildprocess,
LED
1blinksinredinhalfsecondintervals.Whentherebuildprocessiscomplete,LED1
stopsblinking.
Insomeinstan ces(forexample,ifyoureplaceanonRAIDdrive),youmustinitiatethe
rebuildprocessmanually,asdescribedinSection 3.1.2.
IfyoureplacebothRAIDdrives,youalsoneedtoreinstalltheDP600software.Insucha
case,followtheinstructionsforacleaninstallation
inSection 3.3.Whenyoureinstallthe
software,thesystemautomaticallysynchronizesthetwoRAIDdrives,recreatingthe
originalmirroredRAIDarray(manualrebuildnotrequired).
Forinstructionsonreplacingadrive,seeSection 3.1.1.
Table 1-1 Local Storage LED Conditions
1.5.6 USB 2.0 Port
ThefrontpanelUSB2.0portisprovidedforlicenseloadingfromaUSBflashdriveor
toconnecttheprovidedUSBkeyboard.
Front-Panel LED Condition Failed Physical Drive
1Solidred 1
1Blinksinredin
twosecondintervals
2
1Blinksinredin
halfsecondintervals
RebuildingRAID
2Solidred 3
3Solidred 4
4Solidred 5