Using the Professional Reference Monitor
Theparametersforalltheemulationmodesareidentical.Toedittheseparameters:
1. Pressthedesiredemulationmodekey(
LCD,PDP,CUSTOM 1, or CUSTOM 2),andthen
pressthe
STATUSkey.
Therespectivestatusscreendisplaysthecurrentinputandoutputformats,asshown
intheexampleinFigure 2‐22forthe
LCD Emulation Modestatusscreen.
Figure2‐22
Figure 2-22 LCD Emulation Mode Status Screen
2. PresstheEDITkey.
The
Input FormatandVideo Rangeparametersappearfortherespectivemode,as
shownintheexampleinFigure 2‐23forthe
LCD Mode: Inputscreen.
Figure2‐23
Figure 2-23 LCD Mode: Input Screen
3. Tochangethecurrentsetting,presstheupanddownarrowkeystohighlightthe
desiredparameter,andthenpress
ENTER.
Ifyouarealreadyineditmode,butwanttoedittheseparametersforadifferent
emulationmode,pressthedesiredemulationkeytodisplaytheseparametersforthe
respectivemode.
Youcannotadjustthebrightness,contrast,and luminanceparametersintheemulation
modes.