Technical data

12-4 Notes Regarding Application MKE UL/CSA
DOK-MOTOR*-MKE*UL/CSA*-PR01-EN-P
12.3 Type of construction and mounting orientation
MKE motors are supplied in construction shape B05 for flange mounting.
The permitted mounting orientation according to EN 60034-7:1993 can be
found in the following table.
Permitted mounting orientationMotor
constructi
on shape: Designation Diagram Setup
IM B5
Horizontal, flange
connection on drive
side of flange
IM V1
Vertical, flange
connection on drive
side of flange, drive
shaft downward
B05
IM V3
Vertical, flange
connection on drive
side of flange, drive
shaft downward
Fig. 12-6: Mounting orientation
DANGER
Seeping of liquids! Motors mounted as per IM
V3are are susceptible to seeping liquids that
collect over extended periods at the shaft end,
then penetrate the motor, causing damage.
Þ Make sure that liquids cannot collect at the drive shaft.
Primary coat and housing finish
condition at delivery: black priming (RAL 9005)
Resistance: against weathering, yellowing, chalking,
diluted acids and lyes.
An additional coat may be applied to the housing (maximum. thickness
equals 40 µm).