Technical data
MKE UL/CSA Electrical connections 11-1
DOK-MOTOR*-MKE*UL/CSA*-PR01-EN-P
11 Electrical connections
11.1 Overview of connections
The electrical connections of MKE motors include the following
components:
· a power connection includes a connection for temperature sensors
and holding brake, with single-wire design
· an encoder feedback connection with a standard encoder cable
design, and
· an additional external connector for a grounded conductor or for an
equipotential bonding conductor (according to EN 50014: 1992).
Ex aera
max 75 m
max 1,4 m
MKE DKC
HDS
Ex-
terminal box
metal pipe Encoder cable
Power cable
not scope of delivery
cables in metal pipe
approved Ex terminal box
Ex_con_prinzip.fh7
Fig. 11-1: Connection principle, MKE037 (UL/CSA design)
The power and feedback lines of MKE-UL/CSA motors enter the motor
through a special line duct. The approx. 1.5 meter long connection lines
must be guided through a ¾“ metal pipe into an approved Ex terminal
box; see Fig. 11.2. Standard connection lines lead from the Ex terminal
box to the drive controller.
Power and feedback connection