Technical data

Rexroth IndraDyn T Technical Data 4-1
DOK-MOTOR*-MBT********-PR03-EN-P
4 Technical Data
This chapter contains the technical data and definitions of all motor sizes
and lengths of the IndraDyn T series.
4.1 Definitions
Operating Modes
Bosch Rexroth motors are documented according to the test criteria and
measuring methods of EN 60034-1. Stated technical data refers to
operating modes S1 (continuous operation) and S6 (periodic operation),
each with liquid cooling using water as the cooling medium.
t
Dt
P
Dt
V
T
C
t
P
Q
max
P
V
Q
P
Q
max
P
V
Q
S6S1
MBTDefinitions2.EPS
P: Load
P
V
: Electric losses
Θ: Temperature
Θ
max
: Highest temperature (stator)
t: Time
T
C
: Cycle duration
t
P
: Operating time with constant load
t
V
: Idling time
Fig. 4-1: Operating modes according to EN 60034-1 :1998
Duty Cycle
Operating mode S6 is supplemented by the specification of the duty cylce
(ED). The duty cycle is calculated as follows:
%100
T
t
ED
C
P
⋅⋅
=
==
=
ED: Duty cycle in %
T
C
: Cycle duration
t
P
: Operating time with constant load
Fig. 4-2: Duty cycle