Technical data
10-4 Handling and Transport Rexroth IndraDyn T
DOK-MOTOR*-MBT********-PR03-EN-P
Transport
1
Handhabung ohne Montagering
Handling without mounting ring
Handhabung mit Montagering
Handling with mounting ring
Mbt3.EPS
(1): Ring screw for transport (according to DIN 580)
Fig. 10-3: IndraDyn T transport
Note:
• Use ring screws for transport only in opposite holes. Use only suitable
lifting equipment.
• Place the motor only in the horizontal position on a clean, level base.
• If the fittings on the cooling jacket are damaged, the stator becomes
useless.
Storage
Store the motor only according to the following figure.
Mbt4.EPS
Fig. 10-4: IndraDyn T storage
Note:
• Place the motor only in the horizontal position on a clean, level base.
• Before you store or ship the parts, remove the remaining coolant and
other pollution.
• Use the transport crate to store the motor over a longer time and to
protect it against damage and pollution.