Technical data

Rexroth IndraDyn T Handling and Transport 10-1
DOK-MOTOR*-MBT********-PR03-EN-P
10 Handling and Transport
10.1 Supplied Condition
IndraDyn T motors are delivered in wooden crates. Packing units on
pallets are secured by retaining straps.
CAUTION
Injuries due to uncontrolled movement of the
retaining straps when cutting!
Maintain a sufficient distance and carefully cut the
retaining straps.
Upon delivery, the stator and rotor of size 450 and 530 are connected with
an mounting ring. During transport and storage, the mounting ring must
remain on the motor.
Remove the mounting ring only after finishing and testing the
assembly.
Use the mounting ring for securing the device during disassembly and
return shipment.
MST stators with design ...-ST-... are protected by corrosion protection
wax RIVOLTA K.S.P. 317. The corrosion protection must be kept for
transport and storage.
The contact surfaces of these stators must be cleaned with a suitable
cleanser before mounting (e.g. RIVOLTA A.C.S.3).
Factory Inspection
All IndraDyn T motors undergo the following tests, among others, at the
factory:
High-voltage test according to EN 60034-1 (= VDE 0530-1).
Insulation resistance according to EN 60204-1/1.92, Section 20.3.
Geometric measurement of all mounting sizes.
Inspection by Customer
Since all IndraDyn T motors undergo a standardized inspection
procedure, high-voltage tests on the customer side are not required.
Motors and components could be damaged if they undergo several high-
voltage tests.
CAUTION
Destruction of motor components by improperly
executed high-voltage test! Invalidation of
warranty!
Avoid repeated inspections.
Observe the regulations of EN 60034-1 (= VDE