Technical data
Rexroth IndraDyn T Connection Techniques 8-9
DOK-MOTOR*-MBT********-PR03-EN-P
Handling
PG 36
INS0382 INS0381
INS0482 INS0481 (max. 10 mm²)
Montagewand
max.
6 mm
CLICK
Mounting plate
Plaque de support
MBTconnect4.EPS
Fig. 8-9: IndraDyn T power connector
1. Insert the plug into the connector; pay attention to the coding.
2. Manually tighten the bayonet socket until it audibly locks in.
3. The red marks on the flange socket and the plug should be aligned
when the bayonet connection is locked in.
8.5 Sensors
Encoder
An encoder and encoder connection components are not in the scope of
delivery of the motor. Choose the components according to the
requirements of the machine.
The encoder attachment and the rotation direction of the motor must be
parameterized when the drive controller is commissioned. To do this,
heed the functional descriptions for the drive controller as well as the
definitions in chapter 9.8 “Drive Side and Rotation Direction”.
You can find information about encoder manufacturers in chapter 9.9
“External Components”.
Note:
The cables for connecting the motor encoder and the device control must
have a compatible plug on the motor side. When using components of
different manufacturers, always ensure that the connection system is
compatible.
Temperature Sensors
To ensure a reliable motor protection, the temperature sensor
SNM.150.DK must be connected to the drive controller. The connection is
made according to the diagram in Figs. 8-5 or 8-8. For further notes
regarding the temperature sensors, please refer to Chapter 9.6, "Motor
Temperature Monitor”.