Technical data
8-8 Connection Techniques Rexroth IndraDyn T
DOK-MOTOR*-MBT********-PR03-EN-P
8.4 Connection with Coupling
A1
M
3
E
H
A
B
G
D
1
Antriebsregelgerät
Drive controller
Zu
In
Ab
Out
Kühlsystem
Cooling unit
Motorkühlung
Motor cooling
2
3
KTY84-130
SNM150
PTC
PTC
GNYE
1
2
3
A2
A3
Stecker
Plug
F
C
Flanschdose/Kupplung
Flange socket/coupling
6
7
5
8
+
-
MBTconnect3.EPS
(1) Shield connection via cable clamping of the cable strain relief within
the PG thread.
(2): Connect temperature sensor SNM.150.DK (for protecting the motor)
to the drive controller.
(3): Use temperature sensor KTY84-130 only for external temperature
measurement
Fig. 8-8: Sample coupling connection
Coupling and Connector
Choose the coupling with the corresponding connector and the necessary
connecting diameter according to the motor data sheet.
Order designation: INS0382/LXX or INS0482/LXX
• ../L = Solder version
(contact pin with solder contact)
• ../..XX = Connection diameter (e.g. 6 mm² = 06)
The coupling and connector to connect IndraDyn T motors have a
bayonet socket and are not in the scope of delivery.
Note:
• When assembling the connection with crimp contacts, special tools
are necessary.
• For more information about creating cables and connectors as well as
technical data, see the documentation “Rexroth Connection Cables”
MNR. R911282688.
• INS0482 connectors are only suitable for a cross-sectional diameters
up to 10 mm².