Technical data

8-8 Connection Techniques Rexroth IndraDyn T
DOK-MOTOR*-MBT********-PR03-EN-P
8.4 Connection with Coupling
A1
M
3
E
H
A
B
G
D
1
Antriebsregelgerät
Drive controller
Zu
In
Ab
Out
Kühlsystem
Cooling unit
Motorkühlung
Motor cooling
2
3
KTY84-130
SNM150
PTC
PTC
GNYE
1
2
3
A2
A3
Stecker
Plug
F
C
Flanschdose/Kupplung
Flange socket/coupling
6
7
5
8
+
-
MBTconnect3.EPS
(1) Shield connection via cable clamping of the cable strain relief within
the PG thread.
(2): Connect temperature sensor SNM.150.DK (for protecting the motor)
to the drive controller.
(3): Use temperature sensor KTY84-130 only for external temperature
measurement
Fig. 8-8: Sample coupling connection
Coupling and Connector
Choose the coupling with the corresponding connector and the necessary
connecting diameter according to the motor data sheet.
Order designation: INS0382/LXX or INS0482/LXX
../L = Solder version
(contact pin with solder contact)
../..XX = Connection diameter (e.g. 6 mm² = 06)
The coupling and connector to connect IndraDyn T motors have a
bayonet socket and are not in the scope of delivery.
Note:
When assembling the connection with crimp contacts, special tools
are necessary.
For more information about creating cables and connectors as well as
technical data, see the documentation Rexroth Connection Cables
MNR. R911282688.
INS0482 connectors are only suitable for a cross-sectional diameters
up to 10 mm².