Technical data

Rexroth IndraDyn T Connection Techniques 8-3
DOK-MOTOR*-MBT********-PR03-EN-P
Stator
Connection
cable
Connection
wire cross-
section
Control wire
cross-
section
Width across
corners [E] for
PG threads
Diameter
[D] +/- 1mm
Permitted
bending
radius [R]
MST130x-...NS-.. Single wires 1.5mm² 1.0mm² - / - 15mm 10
MST130x-...-FT-..
MST210R-xxxx
INK678
+
L17YC11Y
1.5mm²
- / -
- / -
1.0mm²
23mm
16mm
10.5mm
6mm
MST160x-xxxx
MST210A-0027
MST210C-0027
MST290B-0018
MST290D-0002
INK602 2.5mm² 1.0mm² 34mm 14.8mm
MST210C-0050
MST210E-0027
MST290D-0018
MST290E-0004
MST360B-0018
MST360D-0012
MST360D-0018
INK603 4.0mm²
1.0/
1.5mm²
34mm 16.3mm
MST210D-0070
MST290E-0018
MST450B-0012
MST450D-0006
MST450D-0012
MST450E-0006
MST530B-0010
MST530C-0010
INK604 6.0mm²
1.0/
1.5mm²
34mm 18.5mm
MST360E-0018
MST450E-0012
MST530E-0010
INK605 10.0mm² 1.5mm² 40mm 22.2mm
for fixed installations: 6 x D;
for flexible installations: 10 x D
MST530G-0006
MST530G-0007
MST530L-0006
MST530L-0007
Single wires
2x16.0mm²
per phase
1.5mm² - / - 2 x 9mm 90mm
Fig. 8-3: Connection cables for IndraDyn T stators
The wire designation on the connection cable depends on the selected
stator design and is made as follows: