Technical data

18-6 Assembly MHD Sychronous motors
version 0.1 DOK-MOTOR*-MHD********-PR05-EN-P
If the cable output direction of the power connector of the MHD093
MHD131 motors were not considered when ordering them and now fails
to be the direction desired, it can be turned.
To achieve this, proceed as follows:
1. Loosen the two locking screws (4) and remove the cover of the flange
socket (2).
2. Loosen the four locking screws (3).
3. Now turn the flange socket housing (1) into appropriate position (by
steps in 90°).
4. Ensure that cable strands are prevented from being damaged or
tensioned unnecessarily.
5. Retighten the four locking screws (3) (tightening torque: 3.1 Nm
±10%).
6. Ensure that, when retightening the screws, cable strands and the seal
are prevented from being damaged.
7. Reattach the cover of the flange socket (2) to the connector housing
(1) and retighten the two locking screws (4) (tightening torque: 3.1
Nm ±10%).
O-Ring
3
4
2
1
MG000004v01_MS.fh10
Fig. 18-2: Power connector
Note: The connector output direction can be selected upon ordering
by specifying it accordingly in the type code (output direction A,
B, L, R).
Changing the cable output
direction at
MHD093 MHD131