Technical data

MHD Sychronous motors Notes Application 16-9
DOK-MOTOR*-MHD********-PR05-EN-P
16.5 Liquid Cooling
If subjected to extreme loads, e.g. during continuous start-stop operation
with high repeat frequencies, the motors of the MHD093.-...-...-.N and
MHD115.-...-...-.N motor type series, can be operated with liquid cooling.
The diagram below illustrates the connections of the coolant lines to the
motor types MHD093.-...-...-.N and MHD115.-...-...-.N.
The connection for inlet and outlet is intended for connection elements
with R1/8 thread.
MHD093
Inlet Outlet
Inlet
Outlet
MHD115
X06MH81P.fh10
Fig. 16-15: Liquid cooling of MHD093 and MHD115
If motors are provided with liquid cooling, the liquid connection can be
established in various ways:
Y03MH81P.fh10
Motor
Line Line clip
Coupling
withR1/8" thread
Coupling with
clamped screw
connection
Line
Clamped connection
with R1/8" thread
Quick coupler
connection
Motor
Line olive
MotorClamped
connection
Line
Line olive
withR1/8" thread
DiagrammType of connection
Fig. 16-16: Possible types of connection for liquid cooling
At the moment, it is not possible to procure the connection components
required to this end from Bosch Rexroth. Please refer to the following
documentation for instructions in selecting and dimensioning a heat
disposal system: DOK-DIAX01-DRIVE***LIQ-AUS1-EN-P. It contains
ordering data on the accessories required for liquid cooling and lists the
addresses of manufacturers and suppliers of cooling system components.