Technical data
MHD Sychronous motors Connection System 15-5
DOK-MOTOR*-MHD********-PR05-EN-P
6. Push the heavy-gauge conduit thread (6), the washer (7), the seal (8),
and the plug housing (2) onto the connection cable (3 x 0.75 mm
2
).
7. Strip the outer sheath of the cable for approx. 20 mm, litz wires for 10
mm, and connect it to the plug insert (3) as illustrated above.
8. Push the plug insert (3) into the plug housing (2); fit the cylinder screw
(1); screw the plug to the socket (4).
9. Tighten the heavy-gauge conduit thread (6), while ensuring strain
relief.