Technical data
MHD Sychronous motors MHD131 13-1
DOK-MOTOR*-MHD********-PR05-EN-P
13 MHD131
13.1 Technical data
Descri
p
tion S
y
mbol Unit MHD131B-024
Type of cooling Natural Natural Surface Liquid
Motor overtemperature 60K 100 K 60 K/100 60 K/100
Electric
p
arameters
Characteristic motor speed n
K
min
-1
2000
Continuous torque at standstill M
dN
Nm 85.0 127.5
Continuous current at standstill I
dN
A 51.4 77.1
Peak current I
ma
x
A 231
Torque constant at 20 °C
1
)K
m
Nm/A 1.82
Voltage constant at 20 °CK
E
(
eff
)
V/1000min
-1
158.2
Winding resistance at 20 °CR12
Ω
0.17
Winding inductivity L12 mH 5.2
Number of pole pairs p 4
Rated data
2
)
Rated speed n
N
min
-1
1500 1500
Rated torque M
N
Nm 33.6 96.8
Rated current I
N
A 14.4
in
41.4
not
Rated performance P
N
kW 6.0
Preparation
17.5
available
Rated voltage U
N
V 244 279
Rated frequency f
N
Hz 100 100
Mechanical
p
arameters
Moment of inertia of the rotor J
M
kgm² 232 x 10
-4
Theoretical maximum torque M
ma
x
Nm 220
Minimum strand cross-section
4
)Smm
2
6.0 25.0
time constant T
th
min 100 45
Maximum speed n
ma
x
min
-1
3000
Motor mass
3
)
5
)mkg 84
Perm. stor. a. transport temperature T
L
°C -20 to +80
Permissible ambient temperature
6
)T
um
°C 0 to 40
Maximum setup hei
g
ht
6
)
h m 1000 above MSL
Degree of protection
7
)IP65
Insulation class (according to DIN VDE 0530 Part 1) F
Housing varnish Prime coat black in a/w RAL 9005
1
)
2
)
3
)
4
)
5
)
6
)
7
)
K
m
is to be used for calculations with crest values (I
dN
, I
max
). For calculations with root-mean-square values (rated data), the
torque constant K
m
must be multiplied by a factor of
2
.
Values determined according to EN 60034-1. Current and voltage specified as root-mean-square values.
Without holding brake.
Applicable to Bosch Rexroth cables. Rated according to VDE0298-4 (1992) and installation type B2 according to EN 60204-1
(1993) at an ambient temperature of 40 °C.
Without blower unit.
If the limits specified are exceeded, the performance data must be reduced if necessary. For reduction factors, refer to the
chapter entitled “Environmental Conditions”.
Provided the power and encoder cables are mounted properly.
Fig. 13-1: Technical data of MHD131B-024