Technical data
MHD Sychronous motors MHD115 12-19
DOK-MOTOR*-MHD********-PR05-EN-P
12.6 Blower Units
MHD motors can also be delivered with optional fan units. Please refer to
the “Surface” column of the data sheets for performance data of surface-
cooled motors. The mechanical dimensions of the fan units are
represented in the dimension drawings. The possibilities of combining
motor and fan unit and the technical data of the fans are represented in
the table below.
Motor Ordering name of fan unit
LEM –
RB112C1XX
LEM –
RB112C2XX
LEM –
AB112X121
LEM –
AB112X221
MHD115A-xxx-xxx-Axxxx --- --- x x
MHD115B-xxx-xxx-Axxxx x x x x
MHD115C-xxx-xxx-Axxxx x x x x
--- Fan installation not possible; x Fan installation possible
Technical data of fan unit
Description Symbol Unit
LEM –
RB112C1XX
LEM –
RB112C2XX
LEM –
AB112X121
LEM –
AB112X221
Type of cooling Radial axial
Air flow
B ⇒ A
blowing
B ⇒ A
blowing
Rated voltage U
n
V
230 V, ± 15%
50 / 60 Hz
115 V, ± 10%
50 / 60 Hz
230 V, ± 15%
50 / 60 Hz
115 V, ± 10%
50 / 60 Hz
Power consumption S
n
VA 45 / 43 40 / 39 45 / 43 40 / 39
Rated current I A 0.31 / 0.25 0.53 / 0.46 0.31 / 0.25 0.53 / 0.46
Mean air volume V m³/h 340 390 340 390
Fan unit mass m
L
kg 1.2 1.1 1.2 1.1
Noise level dB(A) 48 / 52 48 / 52 48 / 52 48 / 52
Fig. 12-19: Technical data of MHD115 fan units (optional)
blower_rad115.fh10
unten links rechts
Mögliche Anordnungen:
(bei Blick von vorne
auf Motorwelle)
156
220
190
33
197