Technical data
12-10 MHD115 MHD Sychronous motors
DOK-MOTOR*-MHD********-PR05-EN-P
Holding brake
Description Symbol Unit Holding brake data
Motor type MHD115
Holding torque M
4
Nm 70.0
Rated voltage U
N
V
DC 24 ± 10%
Rated current I
N
A1.29
Moment of inertia J
B
Kgm² 30 x 10
-4
Connection time t
1
ms 53
Disconnection time t
2
ms 97
Mass m
B
kg 3.8
Fig. 12-10: Technical data of MHD115 holding brake (optional)
Technical Data liquid coolant
Description Symbol Unit Data
motor type MHD115A MHD115B MHD115C
Nominal power loss P
vN
W 1100 1200 1300
Coolant inlet temperature
1)
ϑ###
ein
°C +10 ... +40
Coolant temperature raise at P
vN
∆ϑ
N
°C10
Minimum necessary coolant discharge at
∆ϑ
N
2)
Q
N
l/min 1.5 1.7 1.8
Pressure decrease at Q
N
2)3)
∆p
N
bar 0.8 0.9 1.0
Miximum system pressure p
max
bar 3.0
Volume liquid cooling duct V l 0.09 0.11 0.14
pH-value coolant 6 - 8
Materials with coolant contact Description
Flange, end shield Al Mg 5 F32
Profile Al Mg Si 0,5 F22
O-ring Viton
1) Notice the combination between coolant inlet temperature and real environmental temperature:
the coolant inlet temperature should be max. 5°C under the real environmental temperature (otherwise danger of condensation exists)!
2) at coolant water
3) for deviating discharge values notice the discharge diagram (see chapter 16.5)
Fig. 12-11: Technical data liquid coolant at MHD115