Technical data
Rexroth IndraDyn H Type Codes of IndraDyn H Motors 6-5
DOK-MOTOR*-MBS-H******-PR02-EN-P
3. Motor Frame Length
Within a series, the graduation of increasing motor frame length is
indicated by ID letters in alphabetic order. The higher the motor frame
length, the higher the torque.
Frame lengths are, for example, A, B, C, D and E.
4. Winding Code
The winding codes “0120”, “0170”, etc. differentiate winding variants and
refer to the rated speed.
Example: The rated speed for the winding “0120” is n
N
= 1200 rpm.
.
The
DC bus voltage of 540 V
DC
. is a fixed reference value.
A drive combination is selected based on the corresponding selection
data and operating characteristics.
5. Type of cooling
Generally, IndraDyn H motors are fitted with a stator-cooling jacket. They
are intended to be liquid cooled.
6. Cooling connection
Specifies the position of the cooling connection on the stator.
7. Motor Encoder
IndraDyn H-motors not available with a motor encoders. For information
to the motor encoder, see chapter 9 “Application notes”.
8. Electrical Connection
The electrical connection is made via a 1.5-meter cables with flying
leads.
For more information see chapter 8 “Connection system”.
9. Other designs
Reserved for optional types. You can find a short description in the
appropriate type code, mechanical details in the respective dimension
sheet.
Abbrev. column 7
Abbrev. column 9 10 11 12
Abbrev. column 14
Abbrev. column 15
Abbrev. columns 17 18
Abbrev. columns 19 20
Abbrev. column 22 23 24 25