12.10 Deactivation
In the case of malfunctions, maintenance measures or to deactivate
the motors, proceed as follows:
1. Observe the instructions of the machine documentation.
2. Use the machine-side control commands to bring the drive to a
controlled standstill.
3. Switch off the power and control voltage of the drive controller.
4. Switch off the master switch of the machine and deactivate external
systems according to the instructions of the manufacturer.
5. Secure the machine against accidental movements and against
unauthorized operation.
6. Wait for the discharge time of the electrical systems to expire and
disconnect all electrical connections if necessary. Protect all
electrical cables and contacts against contact with other electric
conducting parts.
7. Document all executed measures in the startup report and the
machine maintenance plan.
12.11 Dismantling
DANGER
Fatal injury due to errors in activating motors
and moving elements!
Do not work on unsecured and operating machines.
Secure the machine against accidental movements
and against unauthorized operation.
Before dismantling, secure the motor and feeder
against falling or movements before disconnecting
the mechanical connections.
Pay attention to the strong magnetic field
surrounding the rotor.
1. Observe the instructions of the machine documentation and the
dismantling instructions.
2. Heed the safety notes and carry out all steps as described in the
instructions in the chapter "Deactivation" (above).
3. Before dismantling, secure the motor and feeder against falling or
movements before disconnecting the mechanical connections.
4. Empty the coolant duct of the motor and dismantle the motor from
the machine. Store the motor properly!
5. Document all executed measures in the startup report and the