Rexroth IndraDyn H Startup, Operation and Maintenance 12-13
DOK-MOTOR*-MBS-H******-PR02-EN-P
12.8 Maintenance and Inspection of Motor components
IndraDyn H motor components do not require maintenance. However,
due to external influences, the motor components can be damaged
during operation. Preventive maintenance should occur within the
service intervals of the machine/system.
Check of Motor and Auxiliary Components
The following points, among others, should be observed during the
preventive check of motor and auxiliary components:
Seal of liquid cooling, hoses and connections
Condition of power can encoder cables
Electrical Check of Motor Components
An electrical defect of a stator can be checked by measuring electrical
characteristics. The following variables are relevant:
Resistance between motor connecting wires 1-2, 2-3 and 1-3
Inductance between motor connecting wires 1-2, 2-3 and 1-3
Insulation resistance between motor connecting wires and guides
The measured values of the resistance and inductance can be
compared with the values specified in chapter 4, Technical Data. The
individual values of the resistance and inductance measured between
connections 1-2, 2-3 and 1-3 should be identical within a specific
tolerance. There can be a phase short-circuit, a fault between windings,
or a short-circuit to ground if one or more values differ significantly.
Note: If the measured values differ to a great degree, consult the
Bosch Rexroth customer service department.
The insulation resistance measured between the motor connecting
wires and ground should be at least 1 M.
Note: If the resistance is too low, consult the Bosch Rexroth
customer service department.
Resistance and inductance
Insulation resistance