Technical data

Rexroth IndraDyn H Startup, Operation and Maintenance 12-3
DOK-MOTOR*-MBS-H******-PR02-EN-P
Materials
Startup can be executed directly via an NC terminal or using special
startup software. The DriveTop startup software makes menu-driven,
custom-designed and motor-specific parameterization and optimization
possible.
A normal Windows PC is required for startup with DriveTop.
For startup using the NC control, access to all drive parameters and
functions must be ensured.
An oscilloscope is needed for drive optimization. It is used to display the
signals, which can be shown via the adjustable analog output of the drive
controller. Signals that can be displayed include the command and actual
values of the speed, position or voltage, position lag, intermediate circuit
performance, etc.
A multimeter with the possibility of measuring voltages and resistances
can be helpful for troubleshooting and checking the components .
DriveTop startup software
PC
Startup via NC
Oscilloscope
Multimeter