Technical data
Rexroth IndraDyn H Assembly Instructions 11-17
DOK-MOTOR*-MBS-H******-PR02-EN-P
End stop
Mounting
dimension A
ANSCHL_H_EN.EPS
Fig. 11-16: Example for an end stop for use during removal
Rotor Measurement
A (mm)
MRS 102 i.p.
MRS 142 i.p.
MRS 162 min. 80
MRS 182 min. 90
MRS 202 min. 90
MRS 242 min. 100
MRS 272 min. 110
MRS 312 min. 130
MRS 382 min. 140
Fig. 11-17: Mounting dimension A for various rotor types
4. Connect the oil pump.
Use oil with a viscosity of 900 mm
2
/s at +20°C!
WARNING
Risk of injury from sudden rotor movements!
⇒ The rotor can suddenly slide off the spindle when oil
is pumped into the step interference fit.
⇒ The spindle must be equipped with an arresting
device when pumping oil in.
5. Pump oil into the step interference fit.
Note: Oil is exuded!
Have a collecting pan ready.
Slowly increase the oil pressure until the axial force affecting the step
interference fit permits the rotor to slide off the spindle.