Technical data

11-8 Assembly Instructions Rexroth IndraDyn H
DOK-MOTOR*-MBS-H******-PR02-EN-P
Shrink-fitting the Rotor onto the Spindle
1. Carefully heat the rotor in the heating cabinet to at least +135°C, but
no more than 145°C.
Note: If the rotor is not heated to at least +135°C, it is possible for
the spindle to get stuck in the rotor during the shrink-fitting
process before reaching its final position.
WARNUNG
Burns due to hot components with temperatures
above 50°C!
The rotor is hot! Contact leads to serious burn
injuries!
Wear heat-resistant work clothing and heat-
resistant gloves!
2. Cool the spindle to -20°C.
Note: If the spindle is not cooled to at least -20°C, it is possible for
the spindle to get stuck in the rotor during the shrink-fitting
process before reaching its final position.
WARNUNG
Injuries due to supercooled parts with
temperatures down to -20°C!
The spindle is cold!
Wear suitable protective clothing and safety gloves!
3. Place the rotor into the prepared work fixture.
4. Pick the spindle up and quickly slide it into the rotor.