Technical data

Rexroth IndraDyn H Notes Regarding Application 9-3
DOK-MOTOR*-MBS-H******-PR02-EN-P
Maximum permitted shock load (6ms)
Motor frame size
axial radial
102
142
162
182
202
242
272
312
382
i.p. i.p.
Fig. 9-4: Maximum values for shock stress
For storage, transport and operation of the motors, ensure that the
maximum values in Fig. 9-3 and Fig. 9-4 are not exceeded.
The construction and effectiveness of shock-absorbing or shock-
decoupling attachments depends on the application and must be
determined using measurements. This does not lie within the area of
responsibility of the motor manufacturer. Modifications of the motor
construction result in nullification of the warranty.
9.4 Protection Class
The protection class IP00 according to IEC 60529:1989 + A1: 2000
applies for the stator and rotor of the IndraDyn H series. The applicability
of IndraDyn H motors for certain conditions must be checked carefully.
Note: The machine manufacturer is responsible for testing and
execution of suitable measures.
Notice the following list (without any guarantee on completeness).
Use of the motor in damp environment or a high-humidity
atmosphere.
Use of cooling lubricants, aggressive materials or other liquids.
Cleaning procedure with high pressures, steam or jets of water.
Chemical or electro-chemical interaction with subsequent corrosion or
decomposition of motor parts.
Damage of the winding insulation and irreparable damage of the
motor.
Plan suitable covers or seals to protect the motor.
Difficulties
Possible effects
Possible countermeasures