Technical data

Rexroth IndraDyn H Connection Techniques 8-11
DOK-MOTOR*-MBS-H******-PR02-EN-P
Operating Pressure
The 5-bar maximum coolant inlet pressure applies to all IndraDyn H-
motors This value is as measured directly on the coolant connection of
the motor.
Please observe that additional threads or branch connections in the
cooling circuit can reduce the flow and supply pressure of the coolant.
Select generously-dimensioned connection threads and tube diameters.
8.6 Motor Encoder
Encoder and encoder connection components are not in the scope of
delivery of the motor. Choose the components according to the
requirements of the machine.
You can find further information about encoder manufacturers in chapter
9.12, External components.
Note:
The cables for connecting the motor encoder and the device controller
must have a compatible connector on the motor side. When using
components of different manufacturers heed the continuous compatibility
of the connection system.