Technical data

Rexroth IndraDyn H Connection Techniques 8-9
DOK-MOTOR*-MBS-H******-PR02-EN-P
Note:
To protect the motor from thermal over load, connect the
SNM.150.DK temperature sensor to the drive control
device.
Pay attention to the polarity when connecting the KTY84-
130 temperature sensor (see. Fig. 8-11).
grau/grey (-)
rosa/pink (+)
gelb/yellow
blau/blue
grün/green
M
3 ~
blau/blue
W
V
U
GNYE/Ground
PTC
PTC
blau/blue
PTC SNM.150.DK.***
motor protection temperature sensor
connected to drive controller
power connection
lead identification
KTY84-130
sensor external temperature measurement
no connection to drive controller
Adernkenn.EPS
Fig. 8-11: IndraDyn H connection wires
Heed the notes regarding motor temperature control in chapter 9.7,
Motor temperature control.
8.5 Motor Cooling
The coolant connections on the stator can be designed for axial or radial
connections.
You can find more details about dimension, design and position of the
cooling agent connections in chapter 5, Specifications of the particular
motor.
Anschl_Kühl_Axial.EPS
Fig. 8-12: Axial cooling connection
Wire designation
Axial cooling connection