Technical data
8-8 Connection Techniques Rexroth IndraDyn H
DOK-MOTOR*-MBS-H******-PR02-EN-P
Handling
PG 36
INS0382 INS0381
INS0482 INS0481 (max. 10 mm²)
Montagewand
max.
6 mm
CLICK
Mounting plate
Plaque de support
Kupplung.EPS
Fig. 8-9: IndraDyn H Power connector
1. Insert the plug into the coupling; pay attention to the coding.
2. Manually tighten the bayonet socket until it audibly locks in.
The red marks on the flange socket and the plug are aligned when the
bayonet connection is locked in.
8.3 Connection Designations on the Drive Device
The following overview shows the connection and clamp designations for
power connection and the motor temperature monitoring.
Power connector Motor Temperature Overview
REXROTH
Drive device
Terminal block Clamp designations Terminal block Clamp designations
IndraDrive HMS....
IndraDrive HCS....
X5 1, 2, 3 X6
MotTemp+
MotTemp-
Fig. 8-10: Clamp designation on the drive device
8.4 Temperature Sensors
IndraDyn H stators are fitted with two types of temperature sensors:
SNM.150.DK.* and KTY84-130 sensors. The two are referred to as the
“over-temperature-protection” and the “temperature-monitoring” sensors,
tespectively. The SNM.150.DK leads must be connected to the drive to
protect the motor from overheating, whereas the KTY84-130 sensor is
included for the customer to externally monitor the motors operating
temperature if desired.