Technical data

Rexroth IndraDyn H Connection Techniques 8-7
DOK-MOTOR*-MBS-H******-PR02-EN-P
Connection with Coupling
gelb/yellow
blau/blue
grün/green
C
B
A
6
5
3
2
1
GNYE
D
H
E
C
B
A
D
H
E
M
3 ~
W
V
U
GNYE/Ground
G
F
G
F
Flanschdose bzw. Steckkupplung
flange socket
Leistungsstecker
plug
PTC (SNM.150.DK.***)
PTC (KTY84-130)
Antriebs-
regelgerät
drive controller
Anschl_Kuppl.EPS
Fig. 8-8: Connection diagram using a coupling
Choose the coupling with the corresponding connector and the
necessary connecting diameter according to the motor data sheet.
Order designation: INS0382/LXX or INS0482/LXX
../L = Solder version
(contact pin with solder contact)
../..XX = Connection diameter (e.g. 6 mm² = 06)
The coupling and connector to connect IndraDyn H-motors have a
bayonet socket and are not in the scope of delivery.
Note:
When assembling the connection with crimp contacts, special tools
are necessary.
For more information about making cables and connectors ready to
use and technical data see documentation Connection Cables MNR
R911280894.
INS0482 is only suitable for a connection diameter up to 10 mm².