Technical data
Rexroth IndraDyn H Connection Techniques 8-7
DOK-MOTOR*-MBS-H******-PR02-EN-P
Connection with Coupling
gelb/yellow
blau/blue
grün/green
C
B
A
6
5
3
2
1
GNYE
D
H
E
C
B
A
D
H
E
M
3 ~
W
V
U
GNYE/Ground
G
F
G
F
Flanschdose bzw. Steckkupplung
flange socket
Leistungsstecker
plug
PTC (SNM.150.DK.***)
PTC (KTY84-130)
Antriebs-
regelgerät
drive controller
Anschl_Kuppl.EPS
Fig. 8-8: Connection diagram using a coupling
Choose the coupling with the corresponding connector and the
necessary connecting diameter according to the motor data sheet.
Order designation: INS0382/LXX or INS0482/LXX
• ../L = Solder version
(contact pin with solder contact)
• ../..XX = Connection diameter (e.g. 6 mm² = 06)
The coupling and connector to connect IndraDyn H-motors have a
bayonet socket and are not in the scope of delivery.
Note:
• When assembling the connection with crimp contacts, special tools
are necessary.
• For more information about making cables and connectors ready to
use and technical data see documentation “Connection Cables” MNR
R911280894.
• INS0482 is only suitable for a connection diameter up to 10 mm².